Using Air-Conditioning Energy For All Its Worth

In the search of ways to reduce building operating cost and energy consumption in the new US Department of Labor Building, a simple method of improving heat transfer was applied. A Presidential Letter of Commendation was given to Mr. Petritsch for such contribution to energy consumption and more economic management.
Continue Reading
28
Apr

Chiller Efficiency – Why Chiller Manufacturers Fail to Recommend Brush Cleaning Systems

Learn about 3 reasons Why Chiller Manufacturers Fail to Recommend Automatic Brush Cleaning Systems. What is a simple way to keep Chiller Efficiency high?
Continue Reading
High Cooling Tower Water Temperature Range handled with thermal balancing basin.
24
Jan

Thermal Balancing Basin As an Effective Solution for Handling High Cooling Tower Water Temperature Range

Wacon’s thermal balancing basin concept has a proven track record in Europe and Asia and optimizes the operation for both footprint and Capex. Most recently it is applied in combination with the Aquafan cooling tower for further energy savings in operational cost.
Continue Reading
10
Jan

Increase Chiller Efficiency By Means of Tube Cleaning and Thermal Storage

As a property manager of a major hotel, hospital, mall, or event space, the efficiency of the chillers can make a big difference in the electricity costs you incur at the end of the month. In this article, we discuss two strategies that could be used independently or in combination to save on chiller operating...
Continue Reading
14
Dec

Eqobrush Energy Performance Contract for China

Learn how Eqobrush continuous chiller cleaning system helps to improve energy efficiency in Chinese buildings without investment. By avoiding the settlement of any fouling the chillers keep running at optimal performance at all times and >10% electricity can easily be saved.
Continue Reading
25
Oct

Hotel Energy Efficiency – Automatic Chiller Cleaning

The system’s operational principal is simple. A flow reversal valve is installed between the cooling tower and the chiller. Brushes with catch baskets are installed on each tube inside the chiller. By reversing the water flow over the chiller briefly at regular (4-hour) intervals, the brushes travel up and down through the tube, removing all...
Continue Reading
28
Aug

Prevent Heat Exchanger Fouling With Eqobrush Automatic Tube Cleaning Systems

Condenser and heat exchanger tubes need to regular brushing in order to clean and get rid of build-up before scaling sets in. Eqobrush Automatic Tube Cleaning System keeps heat exchanger and condenser tubes in pristine condition without any interruption of operations. The formation of fouling and scaling can be avoided with Eqobrush brushing system’s high-frequency...
Continue Reading
07
Aug

Eqobrush Automatic Chiller Condenser And Heat Exchanger Cleaning System: Save More, Perform More

Eqobrush Automatic Tube Cleaning System is automatic online chiller condenser and heat exchanger cleaning system. It is designed and engineered to provide a solution in the formation of fouling and scaling that usually occurs during the normal process of operation. The brushing system is pre-programmable so it cleans fouling from piping without interruption or shutting...
Continue Reading
20
Jul

High Performing Industrial Water Cooling Technology

Wacon prides itself for having 30 years of experience in cooling tower engineering. Since 1984, they have specialized in providing solutions for industrial cooling towers. The company’s product range can cater any projects in various levels of complexity. Their field of specialisation is in modular mechanical draft cooling towers using fiberglass reinforced plastics or FRP...
Continue Reading
06
Sep

AQUAFAN+ Hybrid Cooling Tower: High performance at lowest Operational Cost

AQUAFAN towers that combine turbine technology with electric fan-motors allow maximum energy saving at high performance jobs. Details in the downloadable Power Point Show (8 MB)
Continue Reading